Red.com Mini-Mag System Operations Instructions Page 25

  • Download
  • Add to my manuals
  • Print
  • Page
    / 44
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 24
MINIMAG-OP-EN - 25 -
BATTERY CHARGING
Charger Specifi cations
Output voltage of 24 Volts
Output current of 18 amps max (Optional)
Input voltage of 110 Volts/ 60 Hz
(220V/50 Hz available)
Automatic shut off circuit
Made for Deep Cycle Batteries
DANGER
Explosive hydrogen gas forms when Batteries are
charging. An open fl ame or spark can cause this gas
to explode. Serious personal injury or property damage
could occur. Only charge the Batteries in this machine
in a well ventilated area.
WARNING
Before you service a Battery, always wear face protec-
tion, protective gloves and protective clothing. Battery
acid or battery explosion can cause serious injuries.
WARNING
The Batteries in this machine contain sulfuric acid,
which causes burns to skin. If battery acid contacts
clothing or skin, rinse the effected area with cold water
immediately. If battery acid gets on your face or in your
eyes, fl ush the area immediately with cold water and
seek medical attention.
CAUTION
Always use the automatic battery charger provided by
the manufacturer of this machine to charge the Batter-
ies of this machine. It is designed to charge the Batter-
ies at the appropriate rate. If you must use a different
charger, disconnect the Batteries before charging to
avoid damage to the electronic speed controller.
EXTERNAL BATTERY CHARGING:
1. Transport machine to a well ventilated area for
charging.
2. Turn the machine off. Tip Tank back.
3. Check the water in each battery (A). Do not charge
the machine unless the water is slightly higher than
the plates. If needed, add enough distilled water to
just slightly cover the plates. Be careful not to over fi ll.
Batteries can overfl ow during charging. Replace caps
before charging.
4. First, plug the red 50 Charger plug into the
machine’s Charger Port (B). While the Charger plug
is connected, plug the charger power cord into a
grounded 110 Volt standard wall outlet (C).
5. The Charger will automatically begin charging and
automatically shut off when fully charged (check
Battery gauge).
6. After the Charger has turned off - First, unplug the
Charger from the wall outlet. Second, unplug the red
50 Charger plug from the machine.
7. Recheck the cell level after charging. If needed, add
distilled water up to the correct level. Be certain to
replace the caps securely and to wipe off the top of the
Batteries with a clean cloth.
WATER LEVEL SHOULD BE
1/8'' ABOVE PLATES
A
B
B
C
Page view 24
1 2 ... 20 21 22 23 24 25 26 27 28 29 30 ... 43 44

Comments to this Manuals

No comments