  • Page
    / 44
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 15
- 16 - MINIMAG-OP-EN
INSTALLING EDGE/ORBITZ PADS:
1. Turn on machine power.
2. Raise the Scrubdeck by depressing the Brush switch
to the UP and OFF position and turn machine power
back off.
3. Select the correct Pads that best meet your cleaning
application. Consult your local dealer for assistance.
4. Remove any Pad previously attached to the EDGE/
ORBITZ Grip Face by pulling down from the corners
(SEE BELOW).
5. Once Grip Face is clear of any Pads, place pad want-
ed for application centered on the Grip Face (This will
leave a ½ overhang on all sides).
6. Press upwards on the Pad to secure it in place (SEE
BELOW).
7. With Pad attached securely to Grip Face of EDGE/
ORBITZ Deck, the machine is ready to use.
LEVELING EDGE/ORBITZ DECKS:
NOTICE
All Scrubdeck’s should be level at time of machine
delivery. If machine Scrubdeck is not level - Contact your
Servicing Dealer.
1. Drive machine to a fl at level surface and turn machine
off.
2. Ensure that Scrubdeck is in full upright position.
3. Turn on machine and depress the brush switch. Just
before the Scrubdeck’s EDGE/ORBITZ Pad touches
the ground, turn machine OFF.
4. Tip Machine Tank back to gain access to the
Scrubdeck’s Adjustable arms.
5. Loosen the Locking Nut (A) on the Adjustable Deck
Arms. Turn the Hexagonal Arm (B) on each side of the
Scrubdeck to level it. Use the levels built into the deck
(SEE BELOW).
6. Extending the Adjustable Arms raise the front and
lowers the rear of the Scrubdeck. After Scrubdeck has
been leveled - tighten Locking Nuts (A).
A
B
NOTICE
NEVER place aggressive Pads (Maroon Prep, Dominator
HD Strip, etc.) directly onto the Grip Face. Always use
Red or Blue Spacer pad to prevent Grip Face damage.
Page view 15
1 2 ... 11 12 13 14 15 16 17 18 19 20 21 ... 43 44

Comments to this Manuals

No comments